INSTALLATION
MANUAL
SECURIT 800L+ CONTROL PANEL
With additional options
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - INSTALLATION

INSTALLATIONMANUALSECURIT 800L+ CONTROL PANELWith additional options

Seite 2 - CONTENTS

9CIRCUIT PROGRAMMING 4 (Range 2-7)Circuits 2 - 7 can be reprogrammed to suit your requirements. Circuit 1 isfixed as a Final exit circuit. Circuit 8

Seite 3

10ENGINEER ACCESS CODE 1-1The engineer access code is programmed to 7890 by default. To changethis code (while in engineering mode):1. Enter 1-1. LED

Seite 4 - SPECIFICATIONS

11FACTORY PROGRAMMING DEFAULTS 9-9Restoring programming Defaults.Enter 9-9, The sounder will give a rapid pipping sound, wait for 5 seconds, anaccept

Seite 5

12ENTRY CIRCUITThis will start the entry timer when activated providing the panel is set.FIRE (for use with smoke detectors etc.)A zone that when act

Seite 6

13THIS INFORMATION SHOULD BE KEPT EITHER INSIDE THE CONTROL PANEL ORWITH THE INSTALLER. IT CAN BE USED TO REFER TO PROGRAMMING DETAILSWHEN NEEDED.ZON

Seite 7 - POWERING UP

14FAULT FINDINGA selection of common known problems and solutions are listed below.Problem Cause AnswerProgrammed 7-5 but zone1 will not isolate in ni

Seite 8 - PROGRAMMING

15Wiring DiagramPlease Note:IntelliSense are always endeavouring to improve quality and specification of all its productsand may alter or amend this p

Seite 9

1CONTENTSWarnings 2Standards 2Warranty Statement 2Product Description 2Available Parts 2Intended use 2Specifications 3Processor Version 3Power Supply

Seite 10 - N/S = Night Set

2WARNINGSProlonged short circuit of any supply can cause damage to the unit. Take the necessaryprecautions in not allowing liquids to spill on or int

Seite 11

3SPECIFICATIONS SPECIFICATION FOR SOFTWARE REVISION NUMBER V3.0The software revision number is located on the top of the main processorPower SupplyM

Seite 12 - GLOSSARY OF TERMS

4INSTALLATIONLocate the control panel out of sight, such as in a hall, under stairs or in acupboard where connection is easy and the detector zone an

Seite 13 - OF TERMS

5Detector reset (L+ when programmed for ID)Some detectors require the removal of power to reset (e.g. Viper Plus® orSmoke detectors). The L+ terminal

Seite 14

6MOUNTING A REMOTE KEYPAD1. Choose the keypad location and then mark the holes for mounting.2. Make sure the cable is run through the backbox.3. Screw

Seite 15 - FAULT FINDING

7To enter engineering mode, enter the engineering code and then press the #(HASH) key. This forces the panel into engineering mode Note: If leftunatt

Seite 16 - IntelliSense UK

8SOUNDER DURATION (sounder ring time) 3-2 (Range 3-20 minutes)Enter 3-2. A new time can be programmed by entering a key fromthe table.Enter 1 3 min