CK-TB530
Range indoor : 244 m
Range outdoor : 162 m
Input voltage : 10.5 ~ 28 Vdc
Current draw receiver : 35 mA
Current draw transmitter: 45 mA
Operating temperature : -20°C ~ 60°C
-35°C ~ 60°C; with optional heater
I
NTRUDER
P
ANELS AND
K
EYPADS
SECURIT RANGE
CK-ST800L - S
ECURIT
800L 8-Z
ONE
C
ONTROL
P
ANEL
Simple to operate residential/light
commercial control panel.
Circuit type : Normally Closed
loops
Mains supply voltage : 230 Vac nominal
Standby battery : 12 V, max. 7
Ah sealed-acid
battery
Siren output : 12 Vdc @ 750 mA
Total auxiliary power : 500 mA, regulated
Maximum output current: 1 A (total)
Panel quiescent : 40 mA.
Operating temperature : 0°C ~ 40°C
Humidity : 10 ~ 90% relative humidity non-condensing
Features : includes a keypad and transformer;
does not have a communicator;
does not have end of line resistors.
CK-ST800L LED - S
ECURIT
800L LED K
EYPAD
For people who have difficulty in using a
keypad, C&K has included a keyswitch
option which is designed to make usage
simpler.
Supply voltage : 12 V.
Quiescent current : 20 mA
Active : 45 mA
Maximum number allowed : six per Securit 800L.
236/236I RANGE
C&K’s 236 and 236i intruder panels are supplied with an on-board
communicator standard which allows up- and downloading and
reporting to central stations. These fully programmable intruder
panels are equipped with innovative, high powered features: dual
split, and back-up reporting, support of all major reporting formats,
alphanumeric LCD and LED keypad compatibility and protection
against unauthorised use and programming.
CK- 236
I
Number of zones : 6 fully programmable zones plus a keypad-
activated panic soft zone
Zone types : alarm, alarm with walk-through, entry, entry
with double delay, 24-hour
Zone timing : entry delay; programmable from 10-300 s
exit delay; programmable from 10-150 s
Circuit type : End Of Line (EOL)
Keypad operation : up to 4 remote keypads
Digital communicator : three 18-digit phone numbers; 2 for
monitoring and one for up-/downloading
User code : six 4-digit user codes; 1 master code and
5 user codes
Engineer access code : 6-digit code required for all programming;
cannot be used to set or un-set
Outputs : internal siren; external siren; latching
strobe; glassbreak- and smoke sensor
resetting output
Supply voltage : 16.5 Vac
Total auxiliary power : 400 mA max.
236i : advanced lightening protection
CK-236.2 LED
Low profile back-lit LED keypad with
tamper switch. Individual LED’s show status
of system and each zone.
Current draw : 35 mA max.
LED indication : 6 zones, power,
service, arm
Cable : 6 core
Quantity per 236/236i : up to 4 keypads
with the 236 and 236i panels
8